Incinerators may be stationary or Rotary depending upon Sold waste and its quantum. These waste incinerators are operated at Min 850 C in Primary chamber and 1050 C in secondary chamber. Thus incinerated solid waste and product of combustion are passed through flue Gas Temp Dilutor, Cyclone separator, and wet Scrubbing system. Before it is exhausted to Atmosphere through Induced draft fan and chimney.
Discharged gas will be pollution controlled within Norms of GPCB for SO2, NOX, HCL and SPM. Incinerator is refractory lined and backed with Cera Wool or with Insulating Bricks. Temprature controller in both Primary and secondary chambers are provided to control required combustion.
Burners are fully automatic and operate on temp of the syetem.Rotary Incinerators are driven by reduction gear arrangement which fully maintain the contact time between Flues and material. From One end Material is loaded and at other end ashes are collected.